Water Getting In Around My Dormer Window

Cheeks, apron, soakers, the small roof above and the window itself. One of the five is letting go.

Call 07476 888638 for a free, no-obligation quote. Available Mon–Sun, 9am–6pm.

Answer first. A dormer is a small building sitting on a roof, and every edge where it meets that roof has to be weathered. There are typically five candidates for a leak: the cheeks at the sides, the apron at the front, the side soakers or step flashings, the small roof over the dormer, and the window unit itself. Nothing else is usually involved.

That is why dormer leaks are so often misdiagnosed as window failures. The window is the thing you can see, so it gets blamed. In practice the flashings and the little roof above cause more trouble than the glazing does.

The five places to look

Working from the top down, this is what we check and what failure looks like at each point.

  • The dormer roof: often a small flat roof, so blistered felt, a split at an upstand or a blocked outlet
  • The cheeks: tile, slate or lead clad sides where fixings have loosened or the cladding has slipped
  • The apron flashing at the front, where lead should dress down over the main roof covering
  • Side soakers or step flashings where the cheek meets the roof slope, the most common single failure
  • The window unit: perished seals, failed pointing to the frame, or a sill that no longer throws water clear

Reading the evidence inside

The internal pattern narrows it down before anyone goes near the roof.

  • Water at the head of the window, above the frame: apron or the dormer roof above
  • Water at one side of the reveal only: the soakers on that side, or driven rain on the windward cheek
  • Water at the cill with no staining above: often the window itself or condensation on the glass
  • Staining spreading across the ceiling inside the dormer: the small roof over it
  • Damp appearing only in wind driven rain from one direction: a cheek or a shallow flashing on that face

Why dormer flashings fail sooner than the rest of the roof

Dormers concentrate water. Rain that would spread across a whole slope is funnelled around the sides of the dormer and down into the small gutters and junctions either side of it. More water, more often, through details made of short pieces of lead with a lot of joints.

Add to that the fact that dormers are often the part of a roof that has been altered, particularly on loft conversions, and you get details that were formed quickly, sometimes with mortar where lead should be. Any cement fillet around a dormer is a temporary detail whether it was sold as one or not.

What you can check safely

From the ground or an opposite window with binoculars, and from inside the room, you can gather most of what a roofer needs. Do not lean out of a dormer window to inspect its own roof.

Note the weather each time the leak appears, including wind direction, and photograph the internal staining with a date. If the dormer is part of a loft conversion, it also helps to know roughly when the work was done.

The repair

Most dormer leaks are put right by renewing lead: a new apron dressed correctly over the tiles, new soakers stepped into the brick or blockwork joints, or a new covering on the dormer roof with upstands taken high enough to keep driven rain out.

Where cheek cladding has slipped, that section is stripped, the sarking or boarding checked, and the cladding refixed properly. If the timber inside a cheek has been wet for years there may be repair work behind the cladding, and we would rather find that at the quoting stage than surprise you with it mid job.

Want a professional to handle it?

Get Your Free, Personalised Quote

Tell us about your roofing job and we'll get back to you as soon as possible.

No spam, no obligation. We'll get back to you as soon as possible.

Free Inspections
Fast Response
Reliable Workmanship
West Glamorgan Coverage

Questions

Is it the window or the roof that is leaking?

Where the water shows tells you a lot. Damp at the head or in the ceiling inside the dormer points at flashings or the dormer roof. Damp only at the cill, with nothing above it, is more likely the unit or condensation.

Why does the dormer only leak when the wind is in one direction?

Driven rain hits one cheek and one side of the flashings. If a soaker is dressed too shallow, water gets pushed over the top edge on that side only.

Can mortar be used around a dormer instead of lead?

It is often found there, but it cracks away from the surrounding materials and then leaks. Lead flashings dressed into the joints are the durable detail.

Does a dormer leak mean the loft conversion was done badly?

Not always, but conversions are where we most often find rushed flashing details. Age, movement and slipped cladding cause plenty of dormer leaks on original dormers too.

Will scaffolding be needed?

Usually some form of safe access is, because dormer work means working on the slope beside it. We include access in the written quote so there are no additions later.